Type: | ECG007 | Name: | ECG/RESP/TEMP Module |
---|---|---|---|
Package: | Standard | ECG Full Lead: | I,II,III ,aVL, AVR, AVF, And V1,V2,V3,V4,V5,V6 |
Warranty: | 1 Year | Weight: | 60g |
Work Current: | <100mA | Power Supply Voltage: | DC From 3.6 V To 6.0 V |
Working Temperature: | Scope: 20-50℃ | Size: | 100*80*25mm |
Gain: | 5mm/mV,10mm/mV,20mm/mV And 40mm/mV | Scanning Speed:: | Changeable With Three Grades 12.5mm/s,25mm/s And 50mm/s |
Elivery Time Mass Production: | About 15 Days (2000pieces) | OEM: | About 25 Days |
Highlight: | fingerprint oem module Spo2,Spo2 Oem Module,ECG fingerprint oem module |
BERRY CHEAP HOT SALES ECG007 fingerprint oem module spo2 oem module ECG module
Technical features:
1. It is our newly designed module, including six parameters (ECG, NIBP, Spo2, Resp, Temp and PR)
2. Provide three /five ECG leads
3. Default Patient Mode is ADULT
4. Five operating modes: Manual measurement mode, Automatic measurement mode,
Continuous measurement mode, Calibration mode and Leakage check mode
5. Small in size, flexible in installment, highly reliable and accurate in testing. Rapid, accurate testing. Continuously work.
Introduction
The YS3000 is a stand-alone external pulse oximetry module that can be externally connected to a multiparameter monitor,or a hand-held oximeter and other devices that require measurement of oxygen saturation. Connecting to your device via a simple TLL interface, the module can measure blood oxygen saturation accurately with a SpO2 sensor.
►Accuracy: ±1 time/minute |
►Resp Chest impedance method or concentration of carbon dioxide at end of respriation |
►Range: 0 time/minute -100 times/minute |
►Accuracy: ±2 time/minute-> 60 times/minute(including baby) |
►Detection precision of respiration rate: ±1 time/minute |
Specification
ECG:
Full lead: I, II, III, aVL, aVR, aVF and V
Gain 5mm/mV, 10mm/mV, 20mm/mV and 40mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width 0.05Hz-100Hz(3dB)
Heart rate:
Scope: 1 times/minute to 300 times/minutes
Accuracy: ±1 time/minute
Variation of heart beat LORENZE drawing:Analysis on heart beat data for the
current 5 minutes with histogram during RR period.
Resp
Chest impedance method or concentration of carbon dioxide at end of respiration
Scope of chest impedance method 0 time/minute – 100 minutes/minute
Precision of chest impedance method 1 time/minute
Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute
(including baby)
Detection precision of respiration rate: ±1 time/minute
Temp
Single/double path
Type: Vascular/surface temperature
Scope:20℃~50℃
Accuracy±0.2℃
Shanghai Berry Electronic Tech Co., Ltd. is located in Shanghai Caohejing High-tech Park, a beautiful low-carbon and environmentally friendly city. We have been devoted to the R&D, manufacturing and sales of medical electronic instruments in the field of monitoring since 2003.
Our Bio-Medical technology has reached the domestic advanced level. Important breakthroughs have been made in non-invasive blood pressure calculation methods, blood oxygen saturation detection, and multi-parameter monitoring systems. After years of development, we have established good cooperative relations with customers worldwide, with annual sales reaching tens of millions dollars.
BERRY always provides customers with high-quality, cost-effective products. It is important for us to maintain good quality.
In 2009, we obtained the production license and product registration certificate that issued by Shanghai.
ln 2014, we passed the EN ISO 13485 quality system certification and CE0123 certification by TÜV SÜD. And we got the 510K for the wrist and handheld pulse oximeter
ln 2015, we got ANVISA, INMETRO Approved.
In 2016, we got FDA510K approved for fingertip pulse oximeter.
In 2018, we got CE0123 approved for Patient Monitor and new watch oximeter
In 2019, we established Shenzhen factory.
In 2022-now, our business growing up rapidly, and have more cooperation partners.